
Ruckus Switch Centralized Managed ICX7150-24-4X1G - 24 + 2 x 1 GbE RJ45, 4 x 1 GbE SFP, 4 x 10 GbE SFP+
Ruckus Switch Centralized Managed ICX7150-24-4X1G adalah Switch dengan 1 GbE RJ45 Ports, quantity, maximum: 24 + 2, 1 GbE SFP Ports, quantity, maximum: 4, 10 GbE SFP+ Ports, quantity, maximum: 4, USB Type-C port (for console management), RJ45 serial port (for serial console management), USB Type-A port (for external file storage), RJ45 Ethernet port (for out of band network management).

Dijual oleh
Yolori Mall
Ruckus Switch Centralized Managed ICX7150-24-4X1G adalah Switch dengan 1 GbE RJ45 Ports, quantity, maximum: 24 + 2; 1 GbE SFP Ports, quantity, maximum: 4; 10 GbE SFP+ Ports, quantity, maximum: 4. Perangkat ini tidak mendukung PoE/PoE+ dan 802.3bt2 (90 W PoE Power per Port). Dari sisi kinerja, tercatat Switching Capacity, maximum: 132 Gb/s; Forwarding capacity (data rate, full duplex): 98 Mpps; Aggregate Stack Bandwidth, maximum: 480 Gb/s. Switch dari Ruckus ini juga dibekali Switches per Stack, maximum: 12; DRAM: 1 GB; NVRAM (Flash): 2 GB; Packet buffer size: 8/10/12/24 port: 2 MB, 48 port: 4 MB; Maximum MAC addresses: 16,384; Maximum VLANs: 4,095; Maximum PVLANs: 32; Maximum STP (spanning trees instances): 254; Maximum VEs: 382; Maximum ARP entries: 4,094; Maximum routes (in hardware): 1,000 (IPv4), 1,000 (IPv6) Next hop address: 4,094; Trunking: Maximum ports per trunk: 8 Maximum trunk groups: 128; Maximum jumbo frame size: 9,216 bytes; QoS priority queues: 8 per port; Multicast groups: 3,072 (Layer 2) 2,048 (Layer 3); Quality of Service (QoS) mencakup ACL Mapping and Marking of ToS/DSCP (CoS); ACL Mapping and Marking of 802.1p; ACL Mapping to Priority Queue; Classifying and Limiting Flows Based on TCP Flags DiffServ Support; Honoring DSCP and 802.1p (CoS); MAC Address Mapping to Priority Queue Priority Queue Management using Weighted Round Robin (WRR), Strict Priority (SP), and a combination of WRR and SP; Traffic management mencakup ACL-based inbound rate limiting and traffic policies; Broadcast, multicast, and unknown unicast rate limiting; Inbound rate limiting per port Outbound rate limiting per port and per queue; SDN features mencakup OpenFlow1 v1.0 and v1.3 dan OpenFlow with hybrid port mode Operates with an OpenDayLight Controller; High availability mencakup Layer 3 VRRP/VRRP-E protocol redundancy, Real-time state synchronization across the stack, Hitless failover and switchover from master to standby stack controller, Hot insertion and removal of stacked units dan Layer 2 VSRP switch redundancy In Service Software Update (ISSU); Layer 2 feature set mencakup 802.1s Multiple Spanning Tree; 802.1x Authentication; Auto MDI/MDIX; BPDU Guard, Root Guard; Dual-Mode VLANs; MAC-based VLANs, Dynamic MAC-based VLAN activation; Dynamic VLAN Assignment; Dynamic Voice VLAN Assignment; Fast Port Span; GVRP: GARP VLAN Registration Protocol; IGMP Snooping (v1/v2/v3); IGMP Proxy for Static Groups; IGMP v2/v3 Fast Leave; Inter-Packet Gap (IPG) adjustment; Link Fault Signaling (LFS); MAC Address Filtering MAC Learning Disable; MLD Snooping (v1/v2); Multi-device Authentication; Per-VLAN Spanning Tree (PVST/PVST+/PRST) Mirroring: Port-based, ACL-based, MAC Filter-based, and; VLAN-based; PIM-SM v2 Snooping; Port Loop Detection; Private VLAN; Remote Fault Notification (RFN); Single-instance Spanning Tree; Trunk Groups (static, LACP); Uni-Directional Link Detection (UDLD); Metro-Ring Protocol (MRP) (v1, v2); Virtual Switch Redundancy Protocol (VSRP); Q-in-Q and selective Q-in-Q; VLAN Mapping Topology Groups; Base Layer 3 IP routing feature set mencakup IPv4 and IPv6 static routes; RIP v1/v2, RIPng; ECMP; Port-based Access Control Lists Layer 3/Layer 4 ACLs; Host routes; Virtual Interfaces; Routed Interfaces; Route-only Support Routing Between Directly Connected Subnets; Premium Layer 3 IP routing feature set with software license mencakup IPv4 and IPv6 dynamic routes; OSPF v2, v3; PIM-SM, PIM-SSM, PIM-DM, PIM passive (IPv4, IPv6) PBR; Virtual Route Redundancy Protocol VRRP (IPv4); VRRP v3 (IPv6) VRRP-E(IPv4/IPv6); MTBF (25°C): 871,931 hours. Perangkat ini mendukung Stacking; sFlow; Layer 3 (STATIC, RIP, OSPF); OpenFlow with Hybrid Port Mode; Campus Fabric Technology; EEE (Energy Efficient Ethernet). Perangkat ini tidak mendukung Redundant Power Option; VRF; IPsec VPN, with service module; BGP; VxLAN; Multi Chassis Trunking (MCT). Untuk manajemen, tersedia Management mencakup DHCP Auto Configuration; Configuration Logging; Digital Optical Monitoring; Display Log Messages on Multiple Terminals; Embedded Web Management (HTTP/HTTPS); Embedded DHCP Server; Industry-standard Command Line Interface (CLI); RUCKUS SmartZone, RUCKUS Cloud, RUCKUS Unleashed; CLI activation of optional software features; USB file management and storage; Macro for batch execution; Out-of-band Ethernet Management; RSPAN; TFTP; TELNET Client and Server SSH / SSH V2; Bootp; SNMPv1/v2c; DHCP Server and DHCP Relay; SNMPv3 Intro to Framework; Architecture for Describing SNMP Framework; SNMP Message Processing and Dispatching; SNMPv3 Applications; SNMPv3 User-based Security Model; SNMP View-based Access Control Model SNMP; sFlow; Network Time Protocol (NTP); Multiple Syslog Servers; SCP; Virtual Cable Tester (VCT) From management MIB, please see the ICX technical documentation at www.ruckusnetworks.com. Untuk keamanan, tersedia Security mencakup 802.1X authentication; MAC authentication; Flexible authentication; Web authentication; DHCP snooping; Dynamic ARP inspection; Neighbor Discovery (ND) Inspection; Bi-level Access Mode (Standard and EXEC Level); EAP pass-through support; IEEE 802.1X username export in sFlow; Protection against Denial of Service (DoS) attacks Authentication, Authorization, and Accounting (AAA); MAC Address Locking MAC Port Security; Advanced Encryption Standard (AES) with SSHv2; RADIUS/TACACS/TACACS+; Secure Copy (SCP); Secure Shell (SSHv2); Protected Ports; Local Username/Password; Change of Authorization (CoA) RFC 5176; Trusted Platform Module; RADSEC (RFC 6614) Encrypted Syslog (RFC 5425). Perangkat ini tidak mendukung MACsec. Switch dari Ruckus ini juga dibekali USB Type-C port (for console management), RJ45 serial port (for serial console management), USB Type-A port (for external file storage) dan RJ45 Ethernet port (for out of band network management). Untuk daya, tercatat Power supply rated maximum (AC): 36 W; Switch power consumption (25°C) mencakup Idle (no PoE load): 14 W, 10% traffic (full PoE load): 24 W dan 100% traffic (full PoE load): 24 W; Switch heat dissipation (25°C) mencakup Idle (no PoE load): 47 BTU/hr, 10% traffic (full PoE load): 81 BTU/hr dan 100% traffic (full PoE load): 82 BTU/hr. Untuk pendinginan, tercatat Airflow: Fanless; Acoustics (25°C, min fan speed): Fanless. Perangkat ini tidak dilengkapi Reversible Airflow Option dan Hot Swap Internal Power Supplies & Fans. Dimensinya 440 (W) × 280 (D) × 43.65 (H) mm. Beratnya 3.8 kg. Untuk lingkungan operasi, tercatat Temperature mencakup Operating Temperatures: 0°C to 45°C dan Storage Temperatures: -40°C to 70°C; Humidity mencakup Operating relative humidity: 5% to 95% at 45°C, non-condensing; Non-operating relative humidity: 0% to 95% at 70°C, non-condensing. Sertifikasi dan kepatuhan standarnya meliputi Electromagnetic emissions: FCC Class A (Part 15); EN 55022/CISPR-22 Class A; VCCI Class A; ICES-003 Electromagnetic Emission; AS/NZS 55022; EN 61000-3-2 Power Line Harmonics; EN 61000-3-3 Voltage Fluctuation and Flicker; EN 61000-6-3 Emission Standard (supersedes: EN 50081-1); Safety: CAN/CSA-C22.2 NO. 60950-1-07; UL 60950-1 Second Edition; IEC 60950-1 Second Edition; EN 60950-1:2006 Safety of Information Technology Equipment; EN 60825-1 Safety of Laser Products—Part 1: Equipment Classification, Requirements and User’s Guide; EN 60825-2 Safety of Laser Products—Part 2: Safety of Optical Fibre Communication Systems; Immunity: EN 61000-6-1 Generic Immunity and Susceptibility (supersedes EN 50082-1); EN 55024 Immunity Characteristics (supersedes EN 61000-4-2 ESD); EN 61000-4-3 Radiated, Radio Frequency, Electromagnetic Field; EN 61000-4-4 Electrical Fast Transient; EN 61000-4-5 Surge; EN 61000-4-6 Conducted Disturbances Induced by Radio-Frequency Fields; EN 61000-4-8 Power Frequency Magnetic Field; EN 61000-4-11 Voltage Dips and Sags; Environmental regulatory compliance: RoHS-compliant (6 of 6); WEEE-compliant. Perlu diperhatikan: - Kabel stacking, kabel konsol USB, kit pemasangan rak switch kompak, dan optik harus dipesan secara terpisah. Ruckus memberikan Ruckus Indonesia Official Warranty selama 12 bulan untuk produk ini.
Garansi
- Warranty Months
- 12
- Warranty Type
- Ruckus Indonesia Official Warranty
Jaminan
- Stock Status
- Tersedia
Spesifikasi Teknis
- I/O Port
- USB Type-C port (for console management): Yes RJ45 serial port (for serial console management): Yes USB Type-A port (for external file storage): Yes RJ45 Ethernet port (for out of band network management): Yes
- Security
- Security: • 802.1X authentication • MAC authentication • Flexible authentication • Web authentication • DHCP snooping • Dynamic ARP inspection • Neighbor Discovery (ND) Inspection • Bi-level Access Mode (Standard and EXEC Level) • EAP pass-through support • IEEE 802.1X username export in sFlow • Protection against Denial of Service (DoS) attacks Authentication, Authorization, and Accounting (AAA) • MAC Address Locking MAC Port Security • Advanced Encryption Standard (AES) with SSHv2 • RADIUS/TACACS/TACACS+ • Secure Copy (SCP) • Secure Shell (SSHv2) • Protected Ports • Local Username/Password • Change of Authorization (CoA) RFC 5176 • Trusted Platform Module • RADSEC (RFC 6614) Encrypted Syslog (RFC 5425) MACsec: No
- Port Count
- 1 GbE RJ45 Ports, quantity, maximum: 24 + 2 1 GbE SFP Ports, quantity, maximum: 4 10 GbE SFP+ Ports, quantity, maximum: 4
- Management
- Management: • DHCP Auto Configuration • Configuration Logging • Digital Optical Monitoring • Display Log Messages on Multiple Terminals • Embedded Web Management (HTTP/HTTPS) • Embedded DHCP Server • Industry-standard Command Line Interface (CLI) • RUCKUS SmartZone, RUCKUS Cloud, RUCKUS Unleashed • CLI activation of optional software features • USB file management and storage • Macro for batch execution • Out-of-band Ethernet Management • RSPAN • TFTP • TELNET Client and Server SSH / SSH V2 • Bootp • SNMPv1/v2c • DHCP Server and DHCP Relay • SNMPv3 Intro to Framework • Architecture for Describing SNMP Framework • SNMP Message Processing and Dispatching • SNMPv3 Applications • SNMPv3 User-based Security Model • SNMP View-based Access Control Model SNMP • sFlow • Network Time Protocol (NTP) • Multiple Syslog Servers • SCP • Virtual Cable Tester (VCT) From management MIB, please see the ICX technical documentation at www.ruckusnetworks.com
- PoE
- PoE/PoE+: No 802.3bt2 (90 W PoE Power per Port): No
- Bandwidth
- Switching Capacity, maximum: 132 Gb/s Forwarding capacity (data rate, full duplex): 98 Mpps Aggregate Stack Bandwidth, maximum: 480 Gb/s
- Cooling
- Airflow: Fanless Acoustics (25°C, min fan speed): Fanless Reversible Airflow Option: No Hot Swap Internal Power Supplies & Fans: No
- Environment
- Temperature: • Operating Temperatures: 0°C to 45°C • Storage Temperatures: -40°C to 70°C Humidity: • Operating relative humidity: 5% to 95% at 45°C, non-condensing • Non-operating relative humidity: 0% to 95% at 70°C, non-condensing
- Certification
- Electromagnetic emissions: FCC Class A (Part 15); EN 55022/CISPR-22 Class A; VCCI Class A; ICES-003 Electromagnetic Emission; AS/NZS 55022; EN 61000-3-2 Power Line Harmonics; EN 61000-3-3 Voltage Fluctuation and Flicker; EN 61000-6-3 Emission Standard (supersedes: EN 50081-1) Safety: CAN/CSA-C22.2 NO. 60950-1-07; UL 60950-1 Second Edition; IEC 60950-1 Second Edition; EN 60950-1:2006 Safety of Information Technology Equipment; EN 60825-1 Safety of Laser Products—Part 1: Equipment Classification, Requirements and User’s Guide; EN 60825-2 Safety of Laser Products—Part 2: Safety of Optical Fibre Communication Systems Immunity: EN 61000-6-1 Generic Immunity and Susceptibility (supersedes EN 50082-1); EN 55024 Immunity Characteristics (supersedes EN 61000-4-2 ESD); EN 61000-4-3 Radiated, Radio Frequency, Electromagnetic Field; EN 61000-4-4 Electrical Fast Transient; EN 61000-4-5 Surge; EN 61000-4-6 Conducted Disturbances Induced by Radio-Frequency Fields; EN 61000-4-8 Power Frequency Magnetic Field; EN 61000-4-11 Voltage Dips and Sags Environmental regulatory compliance: RoHS-compliant (6 of 6); WEEE-compliant
- Features
- Switches per Stack, maximum: 12 Stacking: Yes sFlow: Yes Layer 3 (STATIC, RIP, OSPF): Yes OpenFlow with Hybrid Port Mode: Yes Campus Fabric Technology: Yes Redundant Power Option: No VRF: No EEE (Energy Efficient Ethernet): Yes IPsec VPN, with service module: No BGP: No VxLAN: No Multi Chassis Trunking (MCT): No DRAM: 1 GB NVRAM (Flash): 2 GB Packet buffer size: 8/10/12/24 port: 2 MB, 48 port: 4 MB Maximum MAC addresses: 16,384 Maximum VLANs: 4,095 Maximum PVLANs: 32 Maximum STP (spanning trees instances): 254 Maximum VEs: 382 Maximum ARP entries: 4,094 Maximum routes (in hardware): 1,000 (IPv4), 1,000 (IPv6) Next hop address: 4,094 Trunking: Maximum ports per trunk: 8 Maximum trunk groups: 128 Maximum jumbo frame size: 9,216 bytes QoS priority queues: 8 per port Multicast groups: 3,072 (Layer 2) 2,048 (Layer 3) Quality of Service (QoS): • ACL Mapping and Marking of ToS/DSCP (CoS) • ACL Mapping and Marking of 802.1p • ACL Mapping to Priority Queue • Classifying and Limiting Flows Based on TCP Flags DiffServ Support • Honoring DSCP and 802.1p (CoS) • MAC Address Mapping to Priority Queue Priority Queue Management using Weighted Round Robin (WRR), Strict Priority (SP), and a combination of WRR and SP Traffic management: • ACL-based inbound rate limiting and traffic policies • Broadcast, multicast, and unknown unicast rate limiting • Inbound rate limiting per port Outbound rate limiting per port and per queue SDN features: • OpenFlow1 v1.0 and v1.3 • OpenFlow with hybrid port mode Operates with an OpenDayLight Controller High availability: • Layer 3 VRRP/VRRP-E protocol redundancy • Real-time state synchronization across the stack • Hitless failover and switchover from master to standby stack controller • Hot insertion and removal of stacked units • Layer 2 VSRP switch redundancy In Service Software Update (ISSU) Layer 2 feature set: • 802.1s Multiple Spanning Tree • 802.1x Authentication • Auto MDI/MDIX • BPDU Guard, Root Guard • Dual-Mode VLANs • MAC-based VLANs, Dynamic MAC-based VLAN activation • Dynamic VLAN Assignment • Dynamic Voice VLAN Assignment • Fast Port Span • GVRP: GARP VLAN Registration Protocol • IGMP Snooping (v1/v2/v3) • IGMP Proxy for Static Groups • IGMP v2/v3 Fast Leave • Inter-Packet Gap (IPG) adjustment • Link Fault Signaling (LFS) • MAC Address Filtering MAC Learning Disable • MLD Snooping (v1/v2) • Multi-device Authentication • Per-VLAN Spanning Tree (PVST/PVST+/PRST) Mirroring: Port-based, ACL-based, MAC Filter-based, and • VLAN-based • PIM-SM v2 Snooping • Port Loop Detection • Private VLAN • Remote Fault Notification (RFN) • Single-instance Spanning Tree • Trunk Groups (static, LACP) • Uni-Directional Link Detection (UDLD) • Metro-Ring Protocol (MRP) (v1, v2) • Virtual Switch Redundancy Protocol (VSRP) • Q-in-Q and selective Q-in-Q • VLAN Mapping Topology Groups Base Layer 3 IP routing feature set: • IPv4 and IPv6 static routes • – RIP v1/v2, RIPng • ECMP • Port-based Access Control Lists Layer 3/Layer 4 ACLs • Host routes • Virtual Interfaces • Routed Interfaces • Route-only Support Routing Between Directly Connected Subnets Premium Layer 3 IP routing feature set with software license: • IPv4 and IPv6 dynamic routes • OSPF v2, v3 • PIM-SM, PIM-SSM, PIM-DM, PIM passive (IPv4, IPv6) PBR • Virtual Route Redundancy Protocol VRRP (IPv4) • VRRP v3 (IPv6) VRRP-E(IPv4/IPv6) MTBF (25°C): 871,931 hours
- Dimensions
- 440 (W) × 280 (D) × 43.65 (H) mm
- Weight
- 3.8 kg
- Power
- Power supply rated maximum (AC): 36 W Switch power consumption (25°C): • Idle (no PoE load): 14 W • 10% traffic (full PoE load): 24 W • 100% traffic (full PoE load): 24 W Switch heat dissipation (25°C): • Idle (no PoE load): 47 BTU/hr • 10% traffic (full PoE load): 81 BTU/hr • 100% traffic (full PoE load): 82 BTU/hr
Bandingkan dengan produk sejenis
Pilihan lain pada kategori yang sama dengan harga berdekatan.
Sedang dilihatRuckusRuckus Switch Centralized Managed ICX7150-24-4X1G - 24 + 2 x 1 GbE RJ45, 4 x 1 GbE SFP, 4 x 10 GbE SFP+ | RuckusRuckus Switch Centralized Managed PoE ICX7150-C12P-2X1G - 12 + 2 x 1 GbE RJ45, 2 x 1 GbE SFP, 2 x 10 GbE SFP+ | RuckusRuckus Switch Stand Alone ICX7150-24-4X1G - 24 + 2 x 1 GbE RJ45, 4 x 1 GbE SFP, 4 x 10 GbE SFP+ | RuckusRuckus Switch Stand Alone PoE ICX7150-24P-4X1G - 24 + 2 x 1 GbE RJ45, 4 x 1 GbE SFP, 4 x 10 GbE SFP+ | |
|---|---|---|---|---|
| Harga | Rp 33.039.000 | Rp 34.279.000 | Rp 26.609.000 | Rp 40.269.000 |
| Garansi | ||||
| Warranty Months | 12 | 12 | 12 | 12 |
| Warranty Type | Ruckus Indonesia Official Warranty | Ruckus Indonesia Official Warranty | Ruckus Indonesia Official Warranty | Ruckus Indonesia Official Warranty |
| Jaminan | ||||
| Stock Status | Tersedia | Tersedia | Tersedia | Tersedia |
| Spesifikasi Teknis | ||||
| I/O Port | USB Type-C port (for console management): Yes RJ45 serial port (for serial console management): Yes USB Type-A port (for external file storage): Yes RJ45 Ethernet port (for out of band network management): Yes | USB Type-C port (for console management): Yes RJ45 serial port (for serial console management): Yes USB Type-A port (for external file storage): Yes RJ45 Ethernet port (for out of band network management): Yes | USB Type-C port (for console management): Yes RJ45 serial port (for serial console management): Yes USB Type-A port (for external file storage): Yes RJ45 Ethernet port (for out of band network management): Yes | USB Type-C port (for console management): Yes RJ45 serial port (for serial console management): Yes USB Type-A port (for external file storage): Yes RJ45 Ethernet port (for out of band network management): Yes |
| Security | Security: • 802.1X authentication • MAC authentication • Flexible authentication • Web authentication • DHCP snooping • Dynamic ARP inspection • Neighbor Discovery (ND) Inspection • Bi-level Access Mode (Standard and EXEC Level) • EAP pass-through support • IEEE 802.1X username export in sFlow • Protection against Denial of Service (DoS) attacks Authentication, Authorization, and Accounting (AAA) • MAC Address Locking MAC Port Security • Advanced Encryption Standard (AES) with SSHv2 • RADIUS/TACACS/TACACS+ • Secure Copy (SCP) • Secure Shell (SSHv2) • Protected Ports • Local Username/Password • Change of Authorization (CoA) RFC 5176 • Trusted Platform Module • RADSEC (RFC 6614) Encrypted Syslog (RFC 5425) MACsec: No | Security: • 802.1X authentication • MAC authentication • Flexible authentication • Web authentication • DHCP snooping • Dynamic ARP inspection • Neighbor Discovery (ND) Inspection • Bi-level Access Mode (Standard and EXEC Level) • EAP pass-through support • IEEE 802.1X username export in sFlow • Protection against Denial of Service (DoS) attacks Authentication, Authorization, and Accounting (AAA) • MAC Address Locking MAC Port Security • Advanced Encryption Standard (AES) with SSHv2 • RADIUS/TACACS/TACACS+ • Secure Copy (SCP) • Secure Shell (SSHv2) • Protected Ports • Local Username/Password • Change of Authorization (CoA) RFC 5176 • Trusted Platform Module • RADSEC (RFC 6614) Encrypted Syslog (RFC 5425) MACsec: No | Security: • 802.1X authentication • MAC authentication • Flexible authentication • Web authentication • DHCP snooping • Dynamic ARP inspection • Neighbor Discovery (ND) Inspection • Bi-level Access Mode (Standard and EXEC Level) • EAP pass-through support • IEEE 802.1X username export in sFlow • Protection against Denial of Service (DoS) attacks Authentication, Authorization, and Accounting (AAA) • MAC Address Locking MAC Port Security • Advanced Encryption Standard (AES) with SSHv2 • RADIUS/TACACS/TACACS+ • Secure Copy (SCP) • Secure Shell (SSHv2) • Protected Ports • Local Username/Password • Change of Authorization (CoA) RFC 5176 • Trusted Platform Module • RADSEC (RFC 6614) Encrypted Syslog (RFC 5425) MACsec: No | Security: • 802.1X authentication • MAC authentication • Flexible authentication • Web authentication • DHCP snooping • Dynamic ARP inspection • Neighbor Discovery (ND) Inspection • Bi-level Access Mode (Standard and EXEC Level) • EAP pass-through support • IEEE 802.1X username export in sFlow • Protection against Denial of Service (DoS) attacks Authentication, Authorization, and Accounting (AAA) • MAC Address Locking MAC Port Security • Advanced Encryption Standard (AES) with SSHv2 • RADIUS/TACACS/TACACS+ • Secure Copy (SCP) • Secure Shell (SSHv2) • Protected Ports • Local Username/Password • Change of Authorization (CoA) RFC 5176 • Trusted Platform Module • RADSEC (RFC 6614) Encrypted Syslog (RFC 5425) MACsec: No |
| Port Count | 1 GbE RJ45 Ports, quantity, maximum: 24 + 2 1 GbE SFP Ports, quantity, maximum: 4 10 GbE SFP+ Ports, quantity, maximum: 4 | 1 GbE RJ45 Ports, quantity, maximum: 12 + 2 1 GbE SFP Ports, quantity, maximum: 2 10 GbE SFP+ Ports, quantity, maximum: 2 | 1 GbE RJ45 Ports, quantity, maximum: 24 + 2 1 GbE SFP Ports, quantity, maximum: 4 10 GbE SFP+ Ports, quantity, maximum: 4 (with license) | 1 GbE RJ45 Ports, quantity, maximum: 24 + 2 1 GbE SFP Ports, quantity, maximum: 4 10 GbE SFP+ Ports, quantity, maximum: 4 |
| Management | Management: • DHCP Auto Configuration • Configuration Logging • Digital Optical Monitoring • Display Log Messages on Multiple Terminals • Embedded Web Management (HTTP/HTTPS) • Embedded DHCP Server • Industry-standard Command Line Interface (CLI) • RUCKUS SmartZone, RUCKUS Cloud, RUCKUS Unleashed • CLI activation of optional software features • USB file management and storage • Macro for batch execution • Out-of-band Ethernet Management • RSPAN • TFTP • TELNET Client and Server SSH / SSH V2 • Bootp • SNMPv1/v2c • DHCP Server and DHCP Relay • SNMPv3 Intro to Framework • Architecture for Describing SNMP Framework • SNMP Message Processing and Dispatching • SNMPv3 Applications • SNMPv3 User-based Security Model • SNMP View-based Access Control Model SNMP • sFlow • Network Time Protocol (NTP) • Multiple Syslog Servers • SCP • Virtual Cable Tester (VCT) From management MIB, please see the ICX technical documentation at www.ruckusnetworks.com | Management: • DHCP Auto Configuration • Configuration Logging • Digital Optical Monitoring • Display Log Messages on Multiple Terminals • Embedded Web Management (HTTP/HTTPS) • Embedded DHCP Server • Industry-standard Command Line Interface (CLI) • RUCKUS SmartZone, RUCKUS Cloud, RUCKUS Unleashed • CLI activation of optional software features • USB file management and storage • Macro for batch execution • Out-of-band Ethernet Management • RSPAN • TFTP • TELNET Client and Server SSH / SSH V2 • Bootp • SNMPv1/v2c • DHCP Server and DHCP Relay • SNMPv3 Intro to Framework • Architecture for Describing SNMP Framework • SNMP Message Processing and Dispatching • SNMPv3 Applications • SNMPv3 User-based Security Model • SNMP View-based Access Control Model SNMP • sFlow • Network Time Protocol (NTP) • Multiple Syslog Servers • SCP • Virtual Cable Tester (VCT) From management MIB, please see the ICX technical documentation at www.ruckusnetworks.com | Management: • DHCP Auto Configuration • Configuration Logging • Digital Optical Monitoring • Display Log Messages on Multiple Terminals • Embedded Web Management (HTTP/HTTPS) • Embedded DHCP Server • Industry-standard Command Line Interface (CLI) • RUCKUS SmartZone, RUCKUS Cloud, RUCKUS Unleashed • CLI activation of optional software features • USB file management and storage • Macro for batch execution • Out-of-band Ethernet Management • RSPAN • TFTP • TELNET Client and Server SSH / SSH V2 • Bootp • SNMPv1/v2c • DHCP Server and DHCP Relay • SNMPv3 Intro to Framework • Architecture for Describing SNMP Framework • SNMP Message Processing and Dispatching • SNMPv3 Applications • SNMPv3 User-based Security Model • SNMP View-based Access Control Model SNMP • sFlow • Network Time Protocol (NTP) • Multiple Syslog Servers • SCP • Virtual Cable Tester (VCT) From management MIB, please see the ICX technical documentation at www.ruckusnetworks.com | Management: • DHCP Auto Configuration • Configuration Logging • Digital Optical Monitoring • Display Log Messages on Multiple Terminals • Embedded Web Management (HTTP/HTTPS) • Embedded DHCP Server • Industry-standard Command Line Interface (CLI) • RUCKUS SmartZone, RUCKUS Cloud, RUCKUS Unleashed • CLI activation of optional software features • USB file management and storage • Macro for batch execution • Out-of-band Ethernet Management • RSPAN • TFTP • TELNET Client and Server SSH / SSH V2 • Bootp • SNMPv1/v2c • DHCP Server and DHCP Relay • SNMPv3 Intro to Framework • Architecture for Describing SNMP Framework • SNMP Message Processing and Dispatching • SNMPv3 Applications • SNMPv3 User-based Security Model • SNMP View-based Access Control Model SNMP • sFlow • Network Time Protocol (NTP) • Multiple Syslog Servers • SCP • Virtual Cable Tester (VCT) From management MIB, please see the ICX technical documentation at www.ruckusnetworks.com |
| PoE | PoE/PoE+: No 802.3bt2 (90 W PoE Power per Port): No | PoE/PoE+: Yes PoE Power Budget, maximum: 124 W 802.3bt2 (90 W PoE Power per Port): No PoE/PoE+ ports: 12 Maximum PoE Class 3 ports (15.4 W per port): 8 Maximum PoE+ Class 4 ports (30 W per port): 4 | PoE/PoE+: No 802.3bt2 (90 W PoE Power per Port): No | PoE/PoE+: Yes PoE Power Budget, maximum: 370 W 802.3bt2 (90 W PoE Power per Port): No PoE/PoE+ ports: 24 Maximum PoE Class 3 ports (15.4 W per port): 24 Maximum PoE+ Class 4 ports (30 W per port): 12 |
| Bandwidth | Switching Capacity, maximum: 132 Gb/s Forwarding capacity (data rate, full duplex): 98 Mpps Aggregate Stack Bandwidth, maximum: 480 Gb/s | Switching Capacity, maximum: 68 Gb/s Forwarding capacity (data rate, full duplex): 51 Mpps Aggregate Stack Bandwidth, maximum: 240 Gb/s | Switching Capacity, maximum: 132 Gb/s Forwarding capacity (data rate, full duplex): 98 Mpps Aggregate Stack Bandwidth, maximum: 480 Gb/s | Switching Capacity, maximum: 132 Gb/s Forwarding capacity (data rate, full duplex): 98 Mpps Aggregate Stack Bandwidth, maximum: 480 Gb/s 64 Byte 1GE 100% Throughput (µs): 2.426 64 Byte 10GE 100% Throughput (µs): 0.961 |
| Cooling | Airflow: Fanless Acoustics (25°C, min fan speed): Fanless Reversible Airflow Option: No Hot Swap Internal Power Supplies & Fans: No | Airflow: Fanless Acoustics (25°C, min fan speed): Fanless Reversible Airflow Option: No Hot Swap Internal Power Supplies & Fans: No | Airflow: Fanless Acoustics (25°C, min fan speed): Fanless Reversible Airflow Option: No Hot Swap Internal Power Supplies & Fans: No | Airflow: Side-to-back Acoustics (25°C, min fan speed): 41.4 dBA Reversible Airflow Option: No Hot Swap Internal Power Supplies & Fans: No |
| Environment | Temperature: • Operating Temperatures: 0°C to 45°C • Storage Temperatures: -40°C to 70°C Humidity: • Operating relative humidity: 5% to 95% at 45°C, non-condensing • Non-operating relative humidity: 0% to 95% at 70°C, non-condensing | Temperature: • Operating Temperatures: 0°C to 45°C • Storage Temperatures: -40°C to 70°C Humidity: • Operating relative humidity: 5% to 95% at 45°C, non-condensing • Non-operating relative humidity: 0% to 95% at 70°C, non-condensing | Temperature: • Operating Temperatures: 0°C to 45°C • Storage Temperatures: -40°C to 70°C Humidity: • Operating relative humidity: 5% to 95% at 45°C, non-condensing • Non-operating relative humidity: 0% to 95% at 70°C, non-condensing | Temperature: • Operating Temperatures: 0°C to 45°C (0°C to 40°C for ICX7150-C10P) • Storage Temperatures: -40°C to 70°C Humidity: • Operating relative humidity: 5% to 95% at 45°C, non-condensing • Non-operating relative humidity: 0% to 95% at 70°C, non-condensing |
| Certification | Electromagnetic emissions: FCC Class A (Part 15); EN 55022/CISPR-22 Class A; VCCI Class A; ICES-003 Electromagnetic Emission; AS/NZS 55022; EN 61000-3-2 Power Line Harmonics; EN 61000-3-3 Voltage Fluctuation and Flicker; EN 61000-6-3 Emission Standard (supersedes: EN 50081-1) Safety: CAN/CSA-C22.2 NO. 60950-1-07; UL 60950-1 Second Edition; IEC 60950-1 Second Edition; EN 60950-1:2006 Safety of Information Technology Equipment; EN 60825-1 Safety of Laser Products—Part 1: Equipment Classification, Requirements and User’s Guide; EN 60825-2 Safety of Laser Products—Part 2: Safety of Optical Fibre Communication Systems Immunity: EN 61000-6-1 Generic Immunity and Susceptibility (supersedes EN 50082-1); EN 55024 Immunity Characteristics (supersedes EN 61000-4-2 ESD); EN 61000-4-3 Radiated, Radio Frequency, Electromagnetic Field; EN 61000-4-4 Electrical Fast Transient; EN 61000-4-5 Surge; EN 61000-4-6 Conducted Disturbances Induced by Radio-Frequency Fields; EN 61000-4-8 Power Frequency Magnetic Field; EN 61000-4-11 Voltage Dips and Sags Environmental regulatory compliance: RoHS-compliant (6 of 6); WEEE-compliant | Electromagnetic emissions: FCC Class A (Part 15); EN 55022/CISPR-22 Class A; VCCI Class A; ICES-003 Electromagnetic Emission; AS/NZS 55022; EN 61000-3-2 Power Line Harmonics; EN 61000-3-3 Voltage Fluctuation and Flicker; EN 61000-6-3 Emission Standard (supersedes: EN 50081-1) Safety: CAN/CSA-C22.2 NO. 60950-1-07; UL 60950-1 Second Edition; IEC 60950-1 Second Edition; EN 60950-1:2006 Safety of Information Technology Equipment; EN 60825-1 Safety of Laser Products—Part 1: Equipment Classification, Requirements and User’s Guide; EN 60825-2 Safety of Laser Products—Part 2: Safety of Optical Fibre Communication Systems Immunity: EN 61000-6-1 Generic Immunity and Susceptibility (supersedes EN 50082-1); EN 55024 Immunity Characteristics (supersedes EN 61000-4-2 ESD); EN 61000-4-3 Radiated, Radio Frequency, Electromagnetic Field; EN 61000-4-4 Electrical Fast Transient; EN 61000-4-5 Surge; EN 61000-4-6 Conducted Disturbances Induced by Radio-Frequency Fields; EN 61000-4-8 Power Frequency Magnetic Field; EN 61000-4-11 Voltage Dips and Sags Environmental regulatory compliance: RoHS-compliant (6 of 6); WEEE-compliant | Electromagnetic emissions: FCC Class A (Part 15); EN 55022/CISPR-22 Class A; VCCI Class A; ICES-003 Electromagnetic Emission; AS/NZS 55022; EN 61000-3-2 Power Line Harmonics; EN 61000-3-3 Voltage Fluctuation and Flicker; EN 61000-6-3 Emission Standard (supersedes: EN 50081-1) Safety: CAN/CSA-C22.2 NO. 60950-1-07; UL 60950-1 Second Edition; IEC 60950-1 Second Edition; EN 60950-1:2006 Safety of Information Technology Equipment; EN 60825-1 Safety of Laser Products—Part 1: Equipment Classification, Requirements and User’s Guide; EN 60825-2 Safety of Laser Products—Part 2: Safety of Optical Fibre Communication Systems Immunity: EN 61000-6-1 Generic Immunity and Susceptibility (supersedes EN 50082-1); EN 55024 Immunity Characteristics (supersedes EN 61000-4-2 ESD); EN 61000-4-3 Radiated, Radio Frequency, Electromagnetic Field; EN 61000-4-4 Electrical Fast Transient; EN 61000-4-5 Surge; EN 61000-4-6 Conducted Disturbances Induced by Radio-Frequency Fields; EN 61000-4-8 Power Frequency Magnetic Field; EN 61000-4-11 Voltage Dips and Sags Environmental regulatory compliance: RoHS-compliant (6 of 6); WEEE-compliant | Electromagnetic emissions: FCC Class A (Part 15); EN 55022/CISPR-22 Class A; VCCI Class A; ICES-003 Electromagnetic Emission; AS/NZS 55022; EN 61000-3-2 Power Line Harmonics; EN 61000-3-3 Voltage Fluctuation and Flicker; EN 61000-6-3 Emission Standard (supersedes: EN 50081-1) Safety: CAN/CSA-C22.2 NO. 60950-1-07; UL 60950-1 Second Edition; IEC 60950-1 Second Edition; EN 60950-1:2006 Safety of Information Technology Equipment; EN 60825-1 Safety of Laser Products—Part 1: Equipment Classification, Requirements and User’s Guide; EN 60825-2 Safety of Laser Products—Part 2: Safety of Optical Fibre Communication Systems Immunity: EN 61000-6-1 Generic Immunity and Susceptibility (supersedes EN 50082-1); EN 55024 Immunity Characteristics (supersedes EN 61000-4-2 ESD); EN 61000-4-3 Radiated, Radio Frequency, Electromagnetic Field; EN 61000-4-4 Electrical Fast Transient; EN 61000-4-5 Surge; EN 61000-4-6 Conducted Disturbances Induced by Radio-Frequency Fields; EN 61000-4-8 Power Frequency Magnetic Field; EN 61000-4-11 Voltage Dips and Sags Environmental regulatory compliance: RoHS-compliant (6 of 6); WEEE-compliant |
| Features | Switches per Stack, maximum: 12 Stacking: Yes sFlow: Yes Layer 3 (STATIC, RIP, OSPF): Yes OpenFlow with Hybrid Port Mode: Yes Campus Fabric Technology: Yes Redundant Power Option: No VRF: No EEE (Energy Efficient Ethernet): Yes IPsec VPN, with service module: No BGP: No VxLAN: No Multi Chassis Trunking (MCT): No DRAM: 1 GB NVRAM (Flash): 2 GB Packet buffer size: 8/10/12/24 port: 2 MB, 48 port: 4 MB Maximum MAC addresses: 16,384 Maximum VLANs: 4,095 Maximum PVLANs: 32 Maximum STP (spanning trees instances): 254 Maximum VEs: 382 Maximum ARP entries: 4,094 Maximum routes (in hardware): 1,000 (IPv4), 1,000 (IPv6) Next hop address: 4,094 Trunking: Maximum ports per trunk: 8 Maximum trunk groups: 128 Maximum jumbo frame size: 9,216 bytes QoS priority queues: 8 per port Multicast groups: 3,072 (Layer 2) 2,048 (Layer 3) Quality of Service (QoS): • ACL Mapping and Marking of ToS/DSCP (CoS) • ACL Mapping and Marking of 802.1p • ACL Mapping to Priority Queue • Classifying and Limiting Flows Based on TCP Flags DiffServ Support • Honoring DSCP and 802.1p (CoS) • MAC Address Mapping to Priority Queue Priority Queue Management using Weighted Round Robin (WRR), Strict Priority (SP), and a combination of WRR and SP Traffic management: • ACL-based inbound rate limiting and traffic policies • Broadcast, multicast, and unknown unicast rate limiting • Inbound rate limiting per port Outbound rate limiting per port and per queue SDN features: • OpenFlow1 v1.0 and v1.3 • OpenFlow with hybrid port mode Operates with an OpenDayLight Controller High availability: • Layer 3 VRRP/VRRP-E protocol redundancy • Real-time state synchronization across the stack • Hitless failover and switchover from master to standby stack controller • Hot insertion and removal of stacked units • Layer 2 VSRP switch redundancy In Service Software Update (ISSU) Layer 2 feature set: • 802.1s Multiple Spanning Tree • 802.1x Authentication • Auto MDI/MDIX • BPDU Guard, Root Guard • Dual-Mode VLANs • MAC-based VLANs, Dynamic MAC-based VLAN activation • Dynamic VLAN Assignment • Dynamic Voice VLAN Assignment • Fast Port Span • GVRP: GARP VLAN Registration Protocol • IGMP Snooping (v1/v2/v3) • IGMP Proxy for Static Groups • IGMP v2/v3 Fast Leave • Inter-Packet Gap (IPG) adjustment • Link Fault Signaling (LFS) • MAC Address Filtering MAC Learning Disable • MLD Snooping (v1/v2) • Multi-device Authentication • Per-VLAN Spanning Tree (PVST/PVST+/PRST) Mirroring: Port-based, ACL-based, MAC Filter-based, and • VLAN-based • PIM-SM v2 Snooping • Port Loop Detection • Private VLAN • Remote Fault Notification (RFN) • Single-instance Spanning Tree • Trunk Groups (static, LACP) • Uni-Directional Link Detection (UDLD) • Metro-Ring Protocol (MRP) (v1, v2) • Virtual Switch Redundancy Protocol (VSRP) • Q-in-Q and selective Q-in-Q • VLAN Mapping Topology Groups Base Layer 3 IP routing feature set: • IPv4 and IPv6 static routes • – RIP v1/v2, RIPng • ECMP • Port-based Access Control Lists Layer 3/Layer 4 ACLs • Host routes • Virtual Interfaces • Routed Interfaces • Route-only Support Routing Between Directly Connected Subnets Premium Layer 3 IP routing feature set with software license: • IPv4 and IPv6 dynamic routes • OSPF v2, v3 • PIM-SM, PIM-SSM, PIM-DM, PIM passive (IPv4, IPv6) PBR • Virtual Route Redundancy Protocol VRRP (IPv4) • VRRP v3 (IPv6) VRRP-E(IPv4/IPv6) MTBF (25°C): 871,931 hours | Switches per Stack, maximum: 12 Stacking: Yes sFlow: Yes Layer 3 (STATIC, RIP, OSPF): Yes OpenFlow with Hybrid Port Mode: Yes Campus Fabric Technology: Yes Redundant Power Option: No VRF: No EEE (Energy Efficient Ethernet): No IPsec VPN, with service module: No BGP: No VxLAN: No Multi Chassis Trunking (MCT): No DRAM: 1 GB NVRAM (Flash): 2 GB Packet buffer size: 8/10/12/24 port: 2 MB, 48 port: 4 MB Maximum MAC addresses: 16,384 Maximum VLANs: 4,095 Maximum PVLANs: 32 Maximum STP (spanning trees instances): 254 Maximum VEs: 382 Maximum ARP entries: 4,094 Maximum routes (in hardware): 1,000 (IPv4), 1,000 (IPv6) Next hop address: 4,094 Trunking: Maximum ports per trunk: 8 Maximum trunk groups: 128 Maximum jumbo frame size: 9,216 bytes QoS priority queues: 8 per port Multicast groups: 3,072 (Layer 2) 2,048 (Layer 3) Quality of Service (QoS): • ACL Mapping and Marking of ToS/DSCP (CoS) • ACL Mapping and Marking of 802.1p • ACL Mapping to Priority Queue • Classifying and Limiting Flows Based on TCP Flags DiffServ Support • Honoring DSCP and 802.1p (CoS) • MAC Address Mapping to Priority Queue Priority Queue Management using Weighted Round Robin (WRR), Strict Priority (SP), and a combination of WRR and SP Traffic management: • ACL-based inbound rate limiting and traffic policies • Broadcast, multicast, and unknown unicast rate limiting • Inbound rate limiting per port Outbound rate limiting per port and per queue SDN features: • OpenFlow1 v1.0 and v1.3 • OpenFlow with hybrid port mode Operates with an OpenDayLight Controller High availability: • Layer 3 VRRP/VRRP-E protocol redundancy • Real-time state synchronization across the stack • Hitless failover and switchover from master to standby stack controller • Hot insertion and removal of stacked units • Layer 2 VSRP switch redundancy In Service Software Update (ISSU) Layer 2 feature set: • 802.1s Multiple Spanning Tree • 802.1x Authentication • Auto MDI/MDIX • BPDU Guard, Root Guard • Dual-Mode VLANs • MAC-based VLANs, Dynamic MAC-based VLAN activation • Dynamic VLAN Assignment • Dynamic Voice VLAN Assignment • Fast Port Span • GVRP: GARP VLAN Registration Protocol • IGMP Snooping (v1/v2/v3) • IGMP Proxy for Static Groups • IGMP v2/v3 Fast Leave • Inter-Packet Gap (IPG) adjustment • Link Fault Signaling (LFS) • MAC Address Filtering MAC Learning Disable • MLD Snooping (v1/v2) • Multi-device Authentication • Per-VLAN Spanning Tree (PVST/PVST+/PRST) Mirroring: Port-based, ACL-based, MAC Filter-based, and • VLAN-based • PIM-SM v2 Snooping • Port Loop Detection • Private VLAN • Remote Fault Notification (RFN) • Single-instance Spanning Tree • Trunk Groups (static, LACP) • Uni-Directional Link Detection (UDLD) • Metro-Ring Protocol (MRP) (v1, v2) • Virtual Switch Redundancy Protocol (VSRP) • Q-in-Q and selective Q-in-Q • VLAN Mapping Topology Groups Base Layer 3 IP routing feature set: • IPv4 and IPv6 static routes • – RIP v1/v2, RIPng • ECMP • Port-based Access Control Lists Layer 3/Layer 4 ACLs • Host routes • Virtual Interfaces • Routed Interfaces • Route-only Support Routing Between Directly Connected Subnets Premium Layer 3 IP routing feature set with software license: • IPv4 and IPv6 dynamic routes • OSPF v2, v3 • PIM-SM, PIM-SSM, PIM-DM, PIM passive (IPv4, IPv6) PBR • Virtual Route Redundancy Protocol VRRP (IPv4) • VRRP v3 (IPv6) VRRP-E(IPv4/IPv6) MTBF (25°C): 562,889 hours | Switches per Stack, maximum: 12 Stacking: Yes sFlow: Yes Layer 3 (static routing and RIP): Yes OpenFlow with Hybrid Port Mode: Yes Campus Fabric Technology: Yes Redundant Power Option: No VRF: No EEE (Energy Efficient Ethernet): Yes IPsec VPN, with service module: No BGP: No VxLAN: No Multi Chassis Trunking (MCT): No DRAM: 1 GB NVRAM (Flash): 2 GB Packet buffer size: 8/10/12/24 port: 2 MB, 48 port: 4 MB Maximum MAC addresses: 16,384 Maximum VLANs: 4,095 Maximum PVLANs: 32 Maximum STP (spanning trees instances): 254 Maximum VEs: 382 Maximum ARP entries: 4,094 Maximum routes (in hardware): 1,000 (IPv4), 1,000 (IPv6) Next hop address: 4,094 Trunking: Maximum ports per trunk: 8 Maximum trunk groups: 128 Maximum jumbo frame size: 9,216 bytes QoS priority queues: 8 per port Multicast groups: 3,072 (Layer 2) 2,048 (Layer 3) Quality of Service (QoS): • ACL Mapping and Marking of ToS/DSCP (CoS) • ACL Mapping and Marking of 802.1p • ACL Mapping to Priority Queue • Classifying and Limiting Flows Based on TCP Flags DiffServ Support • Honoring DSCP and 802.1p (CoS) • MAC Address Mapping to Priority Queue Priority Queue Management using Weighted Round Robin (WRR), Strict Priority (SP), and a combination of WRR and SP Traffic management: • ACL-based inbound rate limiting and traffic policies • Broadcast, multicast, and unknown unicast rate limiting • Inbound rate limiting per port Outbound rate limiting per port and per queue SDN features: • OpenFlow1 v1.0 and v1.3 • OpenFlow with hybrid port mode Operates with an OpenDayLight Controller High availability: • Layer 3 VRRP/VRRP-E protocol redundancy • Real-time state synchronization across the stack • Hitless failover and switchover from master to standby stack controller • Hot insertion and removal of stacked units • Layer 2 VSRP switch redundancy In Service Software Update (ISSU) Layer 2 feature set: • 802.1s Multiple Spanning Tree • 802.1x Authentication • Auto MDI/MDIX • BPDU Guard, Root Guard • Dual-Mode VLANs • MAC-based VLANs, Dynamic MAC-based VLAN activation • Dynamic VLAN Assignment • Dynamic Voice VLAN Assignment • Fast Port Span • GVRP: GARP VLAN Registration Protocol • IGMP Snooping (v1/v2/v3) • IGMP Proxy for Static Groups • IGMP v2/v3 Fast Leave • Inter-Packet Gap (IPG) adjustment • Link Fault Signaling (LFS) • MAC Address Filtering MAC Learning Disable • MLD Snooping (v1/v2) • Multi-device Authentication • Per-VLAN Spanning Tree (PVST/PVST+/PRST) Mirroring: Port-based, ACL-based, MAC Filter-based, and • VLAN-based • PIM-SM v2 Snooping • Port Loop Detection • Private VLAN • Remote Fault Notification (RFN) • Single-instance Spanning Tree • Trunk Groups (static, LACP) • Uni-Directional Link Detection (UDLD) • Metro-Ring Protocol (MRP) (v1, v2) • Virtual Switch Redundancy Protocol (VSRP) • Q-in-Q and selective Q-in-Q • VLAN Mapping Topology Groups Base Layer 3 IP routing feature set: • IPv4 and IPv6 static routes • – RIP v1/v2, RIPng • ECMP • Port-based Access Control Lists Layer 3/Layer 4 ACLs • Host routes • Virtual Interfaces • Routed Interfaces • Route-only Support Routing Between Directly Connected Subnets Premium Layer 3 IP routing feature set with software license: • IPv4 and IPv6 dynamic routes • OSPF v2, v3 • PIM-SM, PIM-SSM, PIM-DM, PIM passive (IPv4, IPv6) PBR • Virtual Route Redundancy Protocol VRRP (IPv4) • VRRP v3 (IPv6) VRRP-E(IPv4/IPv6) MTBF (25°C): 871,931 hours | Switches per Stack, maximum: 12 Stacking: Yes sFlow: Yes Layer 3 (STATIC, RIP, OSPF): Yes OpenFlow with Hybrid Port Mode: Yes Campus Fabric Technology: Yes Redundant Power Option: No VRF: No EEE (Energy Efficient Ethernet): Yes IPsec VPN, with service module: No BGP: No VxLAN: No Multi Chassis Trunking (MCT): No DRAM: 1 GB NVRAM (Flash): 2 GB Packet buffer size: 8/10/12/24 port: 2 MB, 48 port: 4 MB Maximum MAC addresses: 16,384 Maximum VLANs: 4,095 Maximum PVLANs: 32 Maximum STP (spanning trees instances): 254 Maximum VEs: 382 Maximum ARP entries: 4,094 Maximum routes (in hardware): 1,000 (IPv4), 1,000 (IPv6) Next hop address: 4,094 Trunking: Maximum ports per trunk: 8 Maximum trunk groups: 128 Maximum jumbo frame size: 9,216 bytes QoS priority queues: 8 per port Multicast groups: 3,072 (Layer 2) 2,048 (Layer 3) Quality of Service (QoS): • ACL Mapping and Marking of ToS/DSCP (CoS) • ACL Mapping and Marking of 802.1p • ACL Mapping to Priority Queue • Classifying and Limiting Flows Based on TCP Flags DiffServ Support • Honoring DSCP and 802.1p (CoS) • MAC Address Mapping to Priority Queue Priority Queue Management using Weighted Round Robin (WRR), Strict Priority (SP), and a combination of WRR and SP Traffic management: • ACL-based inbound rate limiting and traffic policies • Broadcast, multicast, and unknown unicast rate limiting • Inbound rate limiting per port Outbound rate limiting per port and per queue SDN features: • OpenFlow1 v1.0 and v1.3 • OpenFlow with hybrid port mode Operates with an OpenDayLight Controller High availability: • Layer 3 VRRP/VRRP-E protocol redundancy • Real-time state synchronization across the stack • Hitless failover and switchover from master to standby stack controller • Hot insertion and removal of stacked units • Layer 2 VSRP switch redundancy In Service Software Update (ISSU) Layer 2 feature set: • 802.1s Multiple Spanning Tree • 802.1x Authentication • Auto MDI/MDIX • BPDU Guard, Root Guard • Dual-Mode VLANs • MAC-based VLANs, Dynamic MAC-based VLAN activation • Dynamic VLAN Assignment • Dynamic Voice VLAN Assignment • Fast Port Span • GVRP: GARP VLAN Registration Protocol • IGMP Snooping (v1/v2/v3) • IGMP Proxy for Static Groups • IGMP v2/v3 Fast Leave • Inter-Packet Gap (IPG) adjustment • Link Fault Signaling (LFS) • MAC Address Filtering MAC Learning Disable • MLD Snooping (v1/v2) • Multi-device Authentication • Per-VLAN Spanning Tree (PVST/PVST+/PRST) Mirroring: Port-based, ACL-based, MAC Filter-based, and • VLAN-based • PIM-SM v2 Snooping • Port Loop Detection • Private VLAN • Remote Fault Notification (RFN) • Single-instance Spanning Tree • Trunk Groups (static, LACP) • Uni-Directional Link Detection (UDLD) • Metro-Ring Protocol (MRP) (v1, v2) • Virtual Switch Redundancy Protocol (VSRP) • Q-in-Q and selective Q-in-Q • VLAN Mapping Topology Groups Base Layer 3 IP routing feature set: • IPv4 and IPv6 static routes • – RIP v1/v2, RIPng • ECMP • Port-based Access Control Lists Layer 3/Layer 4 ACLs • Host routes • Virtual Interfaces • Routed Interfaces • Route-only Support Routing Between Directly Connected Subnets Premium Layer 3 IP routing feature set with software license: • IPv4 and IPv6 dynamic routes • OSPF v2, v3 • PIM-SM, PIM-SSM, PIM-DM, PIM passive (IPv4, IPv6) PBR • Virtual Route Redundancy Protocol VRRP (IPv4) • VRRP v3 (IPv6) VRRP-E(IPv4/IPv6) MTBF (25°C): 397,428 hours |
| Dimensions | 440 (W) × 280 (D) × 43.65 (H) mm | 269 (W) × 213 (D) × 43.4 (H) mm | 440 (W) × 280 (D) × 43.65 (H) mm | 440 (W) × 280 (D) × 43.65 (H) mm |
| Weight | 3.8 kg | 2.58 kg | 3.8 kg | 4.93 kg |
| Ordering Information | — | — | RUCKUS ICX 7150 Switch, 24×10/100/1000 Mbps ports, 2×1 GbE RJ45 uplink-ports, 4×1 GbE SFP uplink-ports upgradable to up to 4×10 GbE SFP+ with license, basic Layer 3 (static routing and RIP). | RUCKUS ICX 7150 Switch 24×10/100/1000 Mbps PoE+ ports, 2×1 GbE RJ45 uplink-ports, 4×1 GbE SFP uplink ports upgradable to up to 4×10 GbE SFP+ with license, 370 W PoE budget, basic Layer 3 (static routing and RIP). |
| Power | Power supply rated maximum (AC): 36 W Switch power consumption (25°C): • Idle (no PoE load): 14 W • 10% traffic (full PoE load): 24 W • 100% traffic (full PoE load): 24 W Switch heat dissipation (25°C): • Idle (no PoE load): 47 BTU/hr • 10% traffic (full PoE load): 81 BTU/hr • 100% traffic (full PoE load): 82 BTU/hr | Power supply rated maximum (AC): 150 W Switch power consumption (25°C): • Idle (no PoE load): 20 W • 10% traffic (full PoE load): 157 W • 100% traffic (full PoE load): 157 W Switch heat dissipation (25°C): • Idle (no PoE load): 69 BTU/hr • 10% traffic (full PoE load): 78 BTU/hr • 100% traffic (full PoE load): 79 BTU/hr | Power supply rated maximum (AC): 36 W Switch power consumption (25°C): • Idle (no PoE load): 14 W • 10% traffic (full PoE load): 24 W • 100% traffic (full PoE load): 24 W Switch heat dissipation (25°C): • Idle (no PoE load): 47 BTU/hr • 10% traffic (full PoE load): 81 BTU/hr • 100% traffic (full PoE load): 82 BTU/hr | Power supply rated maximum (AC): 525 W Switch power consumption (25°C): • Idle (no PoE load): 32 W • 10% traffic (full PoE load): 455 W • 100% traffic (full PoE load): 472 W Switch heat dissipation (25°C): • Idle (no PoE load): 108 BTU/hr • 10% traffic (full PoE load): 137 BTU/hr • 100% traffic (full PoE load): 188 BTU/hr |
Ulasan Pembeli
Memuat ulasan...


