Tentang merek· Switch Unmanaged PoEHikvision Switch Unmanaged PoE DS-3E0505P-E/M - 4 Port Gigabit
Hikvision Switch Unmanaged PoE DS-3E0505P-E/M adalah Switch dengan Ports: 4 × Gigabit PoE port,1 × Gigabit RJ45 port, PoE Standard: IEEE 802.3af;IEEE 802.3at, PoE Power Pin: End-span: 1/2(+), 3/6(-), PoE Port: PoE: Ports 1 to 4, Max. Port Power: 30 W, PoE Power Budget: 35 W.

Dijual oleh
Yolori Mall
Hikvision Switch Unmanaged PoE DS-3E0505P-E/M adalah Switch dengan Ports: 4 × Gigabit PoE port,1 × Gigabit RJ45 port. Untuk PoE, tercatat PoE Standard: IEEE 802.3af;IEEE 802.3at; PoE Power Pin: End-span: 1/2(+), 3/6(-); PoE Port: PoE: Ports 1 to 4; Max. Port Power: 30 W; PoE Power Budget: 35 W. Dari sisi kinerja, tercatat Switching Capacity: 10 Gbps; Packet Forwarding Rate: 7.44 Mpps. Switch dari Hikvision ini juga dibekali Model: DS-3E0505P-E/M; Shell: Metal material; Gross Weight: 0.759 kg (1.67 lb); Installation Mode: Desk-Mounted,Wall-Mounted; Surge Protection: 6 kV; MAC Address Table: 2 K; Internal Cache: 1 Mbits. Switch dari Hikvision ini juga dibekali Power Supply: 48 V DC, 0.8 A; Max. Power Consumption: 38 W; Power Consumption in Idle: 3 W. Dimensinya 105 mm × 27.6 mm × 83.1 mm (4.1'' × 1.1'' × 3.3''). Beratnya 0.265 kg (0.58 lb). Untuk lingkungan operasi, tercatat Operating Temperature: 0 °C to 40 °C (32 °F to 104 °F); Storage Temperature: –40 °C to 85 °C (–40 °F to 185 °F); Operating Humidity: 5% to 95% (no condensation); Relative Humidity: 5% to 95% (no condensation). Sertifikasi dan kepatuhan standarnya meliputi EMC mencakup FCC (47 CFR Part 15, Subpart B), CE-EMC (EN 55032: 2015+A11: 2020, EN IEC 61000-3-2: 2019, EN 61000-3-3: 2013+A1: 2019, EN 50130-4: 2011+A1: 2014, EN 55035: 2017+A11: 2020), IC (ICES-003: Issue 7:2020) dan RCM (AS/NZS CISPR 32: 2015); Safety mencakup UL (UL 60950-1), CB (AMD1:2009, AMD2:2013, IEC 62368-1: 2014 (Second Edition) dan CE-LVD (EN 62368-1: 2014+A11: 2017); Chemistry mencakup CE-RoHS (201165EU), WEEE (201219EU) dan Reach (Regulation (EC) No.19072006). Hikvision memberikan Hikvision Indonesia Official Warranty selama 12 bulan untuk produk ini.
Garansi
- Warranty Months
- 12
- Warranty Type
- Hikvision Indonesia Official Warranty
Jaminan
- Stock Status
- Tersedia
Spesifikasi Teknis
- Port Count
- Ports: 4 × Gigabit PoE port,1 × Gigabit RJ45 port
- PoE
- • PoE Standard: IEEE 802.3af;IEEE 802.3at • PoE Power Pin: End-span: 1/2(+), 3/6(-) • PoE Port: PoE: Ports 1 to 4 • Max. Port Power: 30 W • PoE Power Budget: 35 W
- Bandwidth
- • Switching Capacity: 10 Gbps • Packet Forwarding Rate: 7.44 Mpps
- Environment
- • Operating Temperature: 0 °C to 40 °C (32 °F to 104 °F) • Storage Temperature: –40 °C to 85 °C (–40 °F to 185 °F) • Operating Humidity: 5% to 95% (no condensation) • Relative Humidity: 5% to 95% (no condensation)
- Certification
- EMC: • FCC (47 CFR Part 15, • Subpart B), • CE-EMC (EN 55032: 2015+A11: 2020, • EN IEC 61000-3-2: 2019, • EN 61000-3-3: 2013+A1: 2019, • EN 50130-4: 2011+A1: 2014, • EN 55035: 2017+A11: 2020), • IC (ICES-003: Issue 7:2020), • RCM (AS/NZS CISPR 32: 2015) Safety: • UL (UL 60950-1), • CB (AMD1:2009, • AMD2:2013, • IEC 62368-1: 2014 (Second Edition), • CE-LVD (EN 62368-1: 2014+A11: 2017) Chemistry: • CE-RoHS (201165EU); • WEEE (201219EU); • Reach (Regulation (EC) No.19072006)
- Features
- • Model: DS-3E0505P-E/M • Shell: Metal material • Gross Weight: 0.759 kg (1.67 lb) • Installation Mode: Desk-Mounted,Wall-Mounted • Surge Protection: 6 kV • MAC Address Table: 2 K • Internal Cache: 1 Mbits
- Dimensions
- 105 mm × 27.6 mm × 83.1 mm (4.1'' × 1.1'' × 3.3'')
- Weight
- 0.265 kg (0.58 lb)
- Power
- • Power Supply: 48 V DC, 0.8 A • Max. Power Consumption: 38 W • Power Consumption in Idle: 3 W
Bandingkan dengan produk sejenis
Pilihan lain pada kategori yang sama dengan harga berdekatan.
Sedang dilihatHikvisionHikvision Switch Unmanaged PoE DS-3E0505P-E/M - 4 Port Gigabit | RuckusRuckus Switch Stand Alone ICX7150-24-4X1G - 24 + 2 x 1 GbE RJ45, 4 x 1 GbE SFP, 4 x 10 GbE SFP+ | RuckusRuckus Switch Centralized Managed ICX7150-24-4X1G - 24 + 2 x 1 GbE RJ45, 4 x 1 GbE SFP, 4 x 10 GbE SFP+ | RuckusRuckus Switch Centralized Managed PoE ICX7150-C12P-2X1G - 12 + 2 x 1 GbE RJ45, 2 x 1 GbE SFP, 2 x 10 GbE SFP+ | |
|---|---|---|---|---|
| Harga | Rp 1.079.000 | Rp 26.609.000 | Rp 33.039.000 | Rp 34.279.000 |
| Garansi | ||||
| Warranty Months | 12 | 12 | 12 | 12 |
| Warranty Type | Hikvision Indonesia Official Warranty | Ruckus Indonesia Official Warranty | Ruckus Indonesia Official Warranty | Ruckus Indonesia Official Warranty |
| Jaminan | ||||
| Stock Status | Tersedia | Tersedia | Tersedia | Tersedia |
| Spesifikasi Teknis | ||||
| I/O Port | — | USB Type-C port (for console management): Yes RJ45 serial port (for serial console management): Yes USB Type-A port (for external file storage): Yes RJ45 Ethernet port (for out of band network management): Yes | USB Type-C port (for console management): Yes RJ45 serial port (for serial console management): Yes USB Type-A port (for external file storage): Yes RJ45 Ethernet port (for out of band network management): Yes | USB Type-C port (for console management): Yes RJ45 serial port (for serial console management): Yes USB Type-A port (for external file storage): Yes RJ45 Ethernet port (for out of band network management): Yes |
| Security | — | Security: • 802.1X authentication • MAC authentication • Flexible authentication • Web authentication • DHCP snooping • Dynamic ARP inspection • Neighbor Discovery (ND) Inspection • Bi-level Access Mode (Standard and EXEC Level) • EAP pass-through support • IEEE 802.1X username export in sFlow • Protection against Denial of Service (DoS) attacks Authentication, Authorization, and Accounting (AAA) • MAC Address Locking MAC Port Security • Advanced Encryption Standard (AES) with SSHv2 • RADIUS/TACACS/TACACS+ • Secure Copy (SCP) • Secure Shell (SSHv2) • Protected Ports • Local Username/Password • Change of Authorization (CoA) RFC 5176 • Trusted Platform Module • RADSEC (RFC 6614) Encrypted Syslog (RFC 5425) MACsec: No | Security: • 802.1X authentication • MAC authentication • Flexible authentication • Web authentication • DHCP snooping • Dynamic ARP inspection • Neighbor Discovery (ND) Inspection • Bi-level Access Mode (Standard and EXEC Level) • EAP pass-through support • IEEE 802.1X username export in sFlow • Protection against Denial of Service (DoS) attacks Authentication, Authorization, and Accounting (AAA) • MAC Address Locking MAC Port Security • Advanced Encryption Standard (AES) with SSHv2 • RADIUS/TACACS/TACACS+ • Secure Copy (SCP) • Secure Shell (SSHv2) • Protected Ports • Local Username/Password • Change of Authorization (CoA) RFC 5176 • Trusted Platform Module • RADSEC (RFC 6614) Encrypted Syslog (RFC 5425) MACsec: No | Security: • 802.1X authentication • MAC authentication • Flexible authentication • Web authentication • DHCP snooping • Dynamic ARP inspection • Neighbor Discovery (ND) Inspection • Bi-level Access Mode (Standard and EXEC Level) • EAP pass-through support • IEEE 802.1X username export in sFlow • Protection against Denial of Service (DoS) attacks Authentication, Authorization, and Accounting (AAA) • MAC Address Locking MAC Port Security • Advanced Encryption Standard (AES) with SSHv2 • RADIUS/TACACS/TACACS+ • Secure Copy (SCP) • Secure Shell (SSHv2) • Protected Ports • Local Username/Password • Change of Authorization (CoA) RFC 5176 • Trusted Platform Module • RADSEC (RFC 6614) Encrypted Syslog (RFC 5425) MACsec: No |
| Port Count | Ports: 4 × Gigabit PoE port,1 × Gigabit RJ45 port | 1 GbE RJ45 Ports, quantity, maximum: 24 + 2 1 GbE SFP Ports, quantity, maximum: 4 10 GbE SFP+ Ports, quantity, maximum: 4 (with license) | 1 GbE RJ45 Ports, quantity, maximum: 24 + 2 1 GbE SFP Ports, quantity, maximum: 4 10 GbE SFP+ Ports, quantity, maximum: 4 | 1 GbE RJ45 Ports, quantity, maximum: 12 + 2 1 GbE SFP Ports, quantity, maximum: 2 10 GbE SFP+ Ports, quantity, maximum: 2 |
| Management | — | Management: • DHCP Auto Configuration • Configuration Logging • Digital Optical Monitoring • Display Log Messages on Multiple Terminals • Embedded Web Management (HTTP/HTTPS) • Embedded DHCP Server • Industry-standard Command Line Interface (CLI) • RUCKUS SmartZone, RUCKUS Cloud, RUCKUS Unleashed • CLI activation of optional software features • USB file management and storage • Macro for batch execution • Out-of-band Ethernet Management • RSPAN • TFTP • TELNET Client and Server SSH / SSH V2 • Bootp • SNMPv1/v2c • DHCP Server and DHCP Relay • SNMPv3 Intro to Framework • Architecture for Describing SNMP Framework • SNMP Message Processing and Dispatching • SNMPv3 Applications • SNMPv3 User-based Security Model • SNMP View-based Access Control Model SNMP • sFlow • Network Time Protocol (NTP) • Multiple Syslog Servers • SCP • Virtual Cable Tester (VCT) From management MIB, please see the ICX technical documentation at www.ruckusnetworks.com | Management: • DHCP Auto Configuration • Configuration Logging • Digital Optical Monitoring • Display Log Messages on Multiple Terminals • Embedded Web Management (HTTP/HTTPS) • Embedded DHCP Server • Industry-standard Command Line Interface (CLI) • RUCKUS SmartZone, RUCKUS Cloud, RUCKUS Unleashed • CLI activation of optional software features • USB file management and storage • Macro for batch execution • Out-of-band Ethernet Management • RSPAN • TFTP • TELNET Client and Server SSH / SSH V2 • Bootp • SNMPv1/v2c • DHCP Server and DHCP Relay • SNMPv3 Intro to Framework • Architecture for Describing SNMP Framework • SNMP Message Processing and Dispatching • SNMPv3 Applications • SNMPv3 User-based Security Model • SNMP View-based Access Control Model SNMP • sFlow • Network Time Protocol (NTP) • Multiple Syslog Servers • SCP • Virtual Cable Tester (VCT) From management MIB, please see the ICX technical documentation at www.ruckusnetworks.com | Management: • DHCP Auto Configuration • Configuration Logging • Digital Optical Monitoring • Display Log Messages on Multiple Terminals • Embedded Web Management (HTTP/HTTPS) • Embedded DHCP Server • Industry-standard Command Line Interface (CLI) • RUCKUS SmartZone, RUCKUS Cloud, RUCKUS Unleashed • CLI activation of optional software features • USB file management and storage • Macro for batch execution • Out-of-band Ethernet Management • RSPAN • TFTP • TELNET Client and Server SSH / SSH V2 • Bootp • SNMPv1/v2c • DHCP Server and DHCP Relay • SNMPv3 Intro to Framework • Architecture for Describing SNMP Framework • SNMP Message Processing and Dispatching • SNMPv3 Applications • SNMPv3 User-based Security Model • SNMP View-based Access Control Model SNMP • sFlow • Network Time Protocol (NTP) • Multiple Syslog Servers • SCP • Virtual Cable Tester (VCT) From management MIB, please see the ICX technical documentation at www.ruckusnetworks.com |
| PoE | • PoE Standard: IEEE 802.3af;IEEE 802.3at • PoE Power Pin: End-span: 1/2(+), 3/6(-) • PoE Port: PoE: Ports 1 to 4 • Max. Port Power: 30 W • PoE Power Budget: 35 W | PoE/PoE+: No 802.3bt2 (90 W PoE Power per Port): No | PoE/PoE+: No 802.3bt2 (90 W PoE Power per Port): No | PoE/PoE+: Yes PoE Power Budget, maximum: 124 W 802.3bt2 (90 W PoE Power per Port): No PoE/PoE+ ports: 12 Maximum PoE Class 3 ports (15.4 W per port): 8 Maximum PoE+ Class 4 ports (30 W per port): 4 |
| Bandwidth | • Switching Capacity: 10 Gbps • Packet Forwarding Rate: 7.44 Mpps | Switching Capacity, maximum: 132 Gb/s Forwarding capacity (data rate, full duplex): 98 Mpps Aggregate Stack Bandwidth, maximum: 480 Gb/s | Switching Capacity, maximum: 132 Gb/s Forwarding capacity (data rate, full duplex): 98 Mpps Aggregate Stack Bandwidth, maximum: 480 Gb/s | Switching Capacity, maximum: 68 Gb/s Forwarding capacity (data rate, full duplex): 51 Mpps Aggregate Stack Bandwidth, maximum: 240 Gb/s |
| Cooling | — | Airflow: Fanless Acoustics (25°C, min fan speed): Fanless Reversible Airflow Option: No Hot Swap Internal Power Supplies & Fans: No | Airflow: Fanless Acoustics (25°C, min fan speed): Fanless Reversible Airflow Option: No Hot Swap Internal Power Supplies & Fans: No | Airflow: Fanless Acoustics (25°C, min fan speed): Fanless Reversible Airflow Option: No Hot Swap Internal Power Supplies & Fans: No |
| Environment | • Operating Temperature: 0 °C to 40 °C (32 °F to 104 °F) • Storage Temperature: –40 °C to 85 °C (–40 °F to 185 °F) • Operating Humidity: 5% to 95% (no condensation) • Relative Humidity: 5% to 95% (no condensation) | Temperature: • Operating Temperatures: 0°C to 45°C • Storage Temperatures: -40°C to 70°C Humidity: • Operating relative humidity: 5% to 95% at 45°C, non-condensing • Non-operating relative humidity: 0% to 95% at 70°C, non-condensing | Temperature: • Operating Temperatures: 0°C to 45°C • Storage Temperatures: -40°C to 70°C Humidity: • Operating relative humidity: 5% to 95% at 45°C, non-condensing • Non-operating relative humidity: 0% to 95% at 70°C, non-condensing | Temperature: • Operating Temperatures: 0°C to 45°C • Storage Temperatures: -40°C to 70°C Humidity: • Operating relative humidity: 5% to 95% at 45°C, non-condensing • Non-operating relative humidity: 0% to 95% at 70°C, non-condensing |
| Certification | EMC: • FCC (47 CFR Part 15, • Subpart B), • CE-EMC (EN 55032: 2015+A11: 2020, • EN IEC 61000-3-2: 2019, • EN 61000-3-3: 2013+A1: 2019, • EN 50130-4: 2011+A1: 2014, • EN 55035: 2017+A11: 2020), • IC (ICES-003: Issue 7:2020), • RCM (AS/NZS CISPR 32: 2015) Safety: • UL (UL 60950-1), • CB (AMD1:2009, • AMD2:2013, • IEC 62368-1: 2014 (Second Edition), • CE-LVD (EN 62368-1: 2014+A11: 2017) Chemistry: • CE-RoHS (201165EU); • WEEE (201219EU); • Reach (Regulation (EC) No.19072006) | Electromagnetic emissions: FCC Class A (Part 15); EN 55022/CISPR-22 Class A; VCCI Class A; ICES-003 Electromagnetic Emission; AS/NZS 55022; EN 61000-3-2 Power Line Harmonics; EN 61000-3-3 Voltage Fluctuation and Flicker; EN 61000-6-3 Emission Standard (supersedes: EN 50081-1) Safety: CAN/CSA-C22.2 NO. 60950-1-07; UL 60950-1 Second Edition; IEC 60950-1 Second Edition; EN 60950-1:2006 Safety of Information Technology Equipment; EN 60825-1 Safety of Laser Products—Part 1: Equipment Classification, Requirements and User’s Guide; EN 60825-2 Safety of Laser Products—Part 2: Safety of Optical Fibre Communication Systems Immunity: EN 61000-6-1 Generic Immunity and Susceptibility (supersedes EN 50082-1); EN 55024 Immunity Characteristics (supersedes EN 61000-4-2 ESD); EN 61000-4-3 Radiated, Radio Frequency, Electromagnetic Field; EN 61000-4-4 Electrical Fast Transient; EN 61000-4-5 Surge; EN 61000-4-6 Conducted Disturbances Induced by Radio-Frequency Fields; EN 61000-4-8 Power Frequency Magnetic Field; EN 61000-4-11 Voltage Dips and Sags Environmental regulatory compliance: RoHS-compliant (6 of 6); WEEE-compliant | Electromagnetic emissions: FCC Class A (Part 15); EN 55022/CISPR-22 Class A; VCCI Class A; ICES-003 Electromagnetic Emission; AS/NZS 55022; EN 61000-3-2 Power Line Harmonics; EN 61000-3-3 Voltage Fluctuation and Flicker; EN 61000-6-3 Emission Standard (supersedes: EN 50081-1) Safety: CAN/CSA-C22.2 NO. 60950-1-07; UL 60950-1 Second Edition; IEC 60950-1 Second Edition; EN 60950-1:2006 Safety of Information Technology Equipment; EN 60825-1 Safety of Laser Products—Part 1: Equipment Classification, Requirements and User’s Guide; EN 60825-2 Safety of Laser Products—Part 2: Safety of Optical Fibre Communication Systems Immunity: EN 61000-6-1 Generic Immunity and Susceptibility (supersedes EN 50082-1); EN 55024 Immunity Characteristics (supersedes EN 61000-4-2 ESD); EN 61000-4-3 Radiated, Radio Frequency, Electromagnetic Field; EN 61000-4-4 Electrical Fast Transient; EN 61000-4-5 Surge; EN 61000-4-6 Conducted Disturbances Induced by Radio-Frequency Fields; EN 61000-4-8 Power Frequency Magnetic Field; EN 61000-4-11 Voltage Dips and Sags Environmental regulatory compliance: RoHS-compliant (6 of 6); WEEE-compliant | Electromagnetic emissions: FCC Class A (Part 15); EN 55022/CISPR-22 Class A; VCCI Class A; ICES-003 Electromagnetic Emission; AS/NZS 55022; EN 61000-3-2 Power Line Harmonics; EN 61000-3-3 Voltage Fluctuation and Flicker; EN 61000-6-3 Emission Standard (supersedes: EN 50081-1) Safety: CAN/CSA-C22.2 NO. 60950-1-07; UL 60950-1 Second Edition; IEC 60950-1 Second Edition; EN 60950-1:2006 Safety of Information Technology Equipment; EN 60825-1 Safety of Laser Products—Part 1: Equipment Classification, Requirements and User’s Guide; EN 60825-2 Safety of Laser Products—Part 2: Safety of Optical Fibre Communication Systems Immunity: EN 61000-6-1 Generic Immunity and Susceptibility (supersedes EN 50082-1); EN 55024 Immunity Characteristics (supersedes EN 61000-4-2 ESD); EN 61000-4-3 Radiated, Radio Frequency, Electromagnetic Field; EN 61000-4-4 Electrical Fast Transient; EN 61000-4-5 Surge; EN 61000-4-6 Conducted Disturbances Induced by Radio-Frequency Fields; EN 61000-4-8 Power Frequency Magnetic Field; EN 61000-4-11 Voltage Dips and Sags Environmental regulatory compliance: RoHS-compliant (6 of 6); WEEE-compliant |
| Features | • Model: DS-3E0505P-E/M • Shell: Metal material • Gross Weight: 0.759 kg (1.67 lb) • Installation Mode: Desk-Mounted,Wall-Mounted • Surge Protection: 6 kV • MAC Address Table: 2 K • Internal Cache: 1 Mbits | Switches per Stack, maximum: 12 Stacking: Yes sFlow: Yes Layer 3 (static routing and RIP): Yes OpenFlow with Hybrid Port Mode: Yes Campus Fabric Technology: Yes Redundant Power Option: No VRF: No EEE (Energy Efficient Ethernet): Yes IPsec VPN, with service module: No BGP: No VxLAN: No Multi Chassis Trunking (MCT): No DRAM: 1 GB NVRAM (Flash): 2 GB Packet buffer size: 8/10/12/24 port: 2 MB, 48 port: 4 MB Maximum MAC addresses: 16,384 Maximum VLANs: 4,095 Maximum PVLANs: 32 Maximum STP (spanning trees instances): 254 Maximum VEs: 382 Maximum ARP entries: 4,094 Maximum routes (in hardware): 1,000 (IPv4), 1,000 (IPv6) Next hop address: 4,094 Trunking: Maximum ports per trunk: 8 Maximum trunk groups: 128 Maximum jumbo frame size: 9,216 bytes QoS priority queues: 8 per port Multicast groups: 3,072 (Layer 2) 2,048 (Layer 3) Quality of Service (QoS): • ACL Mapping and Marking of ToS/DSCP (CoS) • ACL Mapping and Marking of 802.1p • ACL Mapping to Priority Queue • Classifying and Limiting Flows Based on TCP Flags DiffServ Support • Honoring DSCP and 802.1p (CoS) • MAC Address Mapping to Priority Queue Priority Queue Management using Weighted Round Robin (WRR), Strict Priority (SP), and a combination of WRR and SP Traffic management: • ACL-based inbound rate limiting and traffic policies • Broadcast, multicast, and unknown unicast rate limiting • Inbound rate limiting per port Outbound rate limiting per port and per queue SDN features: • OpenFlow1 v1.0 and v1.3 • OpenFlow with hybrid port mode Operates with an OpenDayLight Controller High availability: • Layer 3 VRRP/VRRP-E protocol redundancy • Real-time state synchronization across the stack • Hitless failover and switchover from master to standby stack controller • Hot insertion and removal of stacked units • Layer 2 VSRP switch redundancy In Service Software Update (ISSU) Layer 2 feature set: • 802.1s Multiple Spanning Tree • 802.1x Authentication • Auto MDI/MDIX • BPDU Guard, Root Guard • Dual-Mode VLANs • MAC-based VLANs, Dynamic MAC-based VLAN activation • Dynamic VLAN Assignment • Dynamic Voice VLAN Assignment • Fast Port Span • GVRP: GARP VLAN Registration Protocol • IGMP Snooping (v1/v2/v3) • IGMP Proxy for Static Groups • IGMP v2/v3 Fast Leave • Inter-Packet Gap (IPG) adjustment • Link Fault Signaling (LFS) • MAC Address Filtering MAC Learning Disable • MLD Snooping (v1/v2) • Multi-device Authentication • Per-VLAN Spanning Tree (PVST/PVST+/PRST) Mirroring: Port-based, ACL-based, MAC Filter-based, and • VLAN-based • PIM-SM v2 Snooping • Port Loop Detection • Private VLAN • Remote Fault Notification (RFN) • Single-instance Spanning Tree • Trunk Groups (static, LACP) • Uni-Directional Link Detection (UDLD) • Metro-Ring Protocol (MRP) (v1, v2) • Virtual Switch Redundancy Protocol (VSRP) • Q-in-Q and selective Q-in-Q • VLAN Mapping Topology Groups Base Layer 3 IP routing feature set: • IPv4 and IPv6 static routes • – RIP v1/v2, RIPng • ECMP • Port-based Access Control Lists Layer 3/Layer 4 ACLs • Host routes • Virtual Interfaces • Routed Interfaces • Route-only Support Routing Between Directly Connected Subnets Premium Layer 3 IP routing feature set with software license: • IPv4 and IPv6 dynamic routes • OSPF v2, v3 • PIM-SM, PIM-SSM, PIM-DM, PIM passive (IPv4, IPv6) PBR • Virtual Route Redundancy Protocol VRRP (IPv4) • VRRP v3 (IPv6) VRRP-E(IPv4/IPv6) MTBF (25°C): 871,931 hours | Switches per Stack, maximum: 12 Stacking: Yes sFlow: Yes Layer 3 (STATIC, RIP, OSPF): Yes OpenFlow with Hybrid Port Mode: Yes Campus Fabric Technology: Yes Redundant Power Option: No VRF: No EEE (Energy Efficient Ethernet): Yes IPsec VPN, with service module: No BGP: No VxLAN: No Multi Chassis Trunking (MCT): No DRAM: 1 GB NVRAM (Flash): 2 GB Packet buffer size: 8/10/12/24 port: 2 MB, 48 port: 4 MB Maximum MAC addresses: 16,384 Maximum VLANs: 4,095 Maximum PVLANs: 32 Maximum STP (spanning trees instances): 254 Maximum VEs: 382 Maximum ARP entries: 4,094 Maximum routes (in hardware): 1,000 (IPv4), 1,000 (IPv6) Next hop address: 4,094 Trunking: Maximum ports per trunk: 8 Maximum trunk groups: 128 Maximum jumbo frame size: 9,216 bytes QoS priority queues: 8 per port Multicast groups: 3,072 (Layer 2) 2,048 (Layer 3) Quality of Service (QoS): • ACL Mapping and Marking of ToS/DSCP (CoS) • ACL Mapping and Marking of 802.1p • ACL Mapping to Priority Queue • Classifying and Limiting Flows Based on TCP Flags DiffServ Support • Honoring DSCP and 802.1p (CoS) • MAC Address Mapping to Priority Queue Priority Queue Management using Weighted Round Robin (WRR), Strict Priority (SP), and a combination of WRR and SP Traffic management: • ACL-based inbound rate limiting and traffic policies • Broadcast, multicast, and unknown unicast rate limiting • Inbound rate limiting per port Outbound rate limiting per port and per queue SDN features: • OpenFlow1 v1.0 and v1.3 • OpenFlow with hybrid port mode Operates with an OpenDayLight Controller High availability: • Layer 3 VRRP/VRRP-E protocol redundancy • Real-time state synchronization across the stack • Hitless failover and switchover from master to standby stack controller • Hot insertion and removal of stacked units • Layer 2 VSRP switch redundancy In Service Software Update (ISSU) Layer 2 feature set: • 802.1s Multiple Spanning Tree • 802.1x Authentication • Auto MDI/MDIX • BPDU Guard, Root Guard • Dual-Mode VLANs • MAC-based VLANs, Dynamic MAC-based VLAN activation • Dynamic VLAN Assignment • Dynamic Voice VLAN Assignment • Fast Port Span • GVRP: GARP VLAN Registration Protocol • IGMP Snooping (v1/v2/v3) • IGMP Proxy for Static Groups • IGMP v2/v3 Fast Leave • Inter-Packet Gap (IPG) adjustment • Link Fault Signaling (LFS) • MAC Address Filtering MAC Learning Disable • MLD Snooping (v1/v2) • Multi-device Authentication • Per-VLAN Spanning Tree (PVST/PVST+/PRST) Mirroring: Port-based, ACL-based, MAC Filter-based, and • VLAN-based • PIM-SM v2 Snooping • Port Loop Detection • Private VLAN • Remote Fault Notification (RFN) • Single-instance Spanning Tree • Trunk Groups (static, LACP) • Uni-Directional Link Detection (UDLD) • Metro-Ring Protocol (MRP) (v1, v2) • Virtual Switch Redundancy Protocol (VSRP) • Q-in-Q and selective Q-in-Q • VLAN Mapping Topology Groups Base Layer 3 IP routing feature set: • IPv4 and IPv6 static routes • – RIP v1/v2, RIPng • ECMP • Port-based Access Control Lists Layer 3/Layer 4 ACLs • Host routes • Virtual Interfaces • Routed Interfaces • Route-only Support Routing Between Directly Connected Subnets Premium Layer 3 IP routing feature set with software license: • IPv4 and IPv6 dynamic routes • OSPF v2, v3 • PIM-SM, PIM-SSM, PIM-DM, PIM passive (IPv4, IPv6) PBR • Virtual Route Redundancy Protocol VRRP (IPv4) • VRRP v3 (IPv6) VRRP-E(IPv4/IPv6) MTBF (25°C): 871,931 hours | Switches per Stack, maximum: 12 Stacking: Yes sFlow: Yes Layer 3 (STATIC, RIP, OSPF): Yes OpenFlow with Hybrid Port Mode: Yes Campus Fabric Technology: Yes Redundant Power Option: No VRF: No EEE (Energy Efficient Ethernet): No IPsec VPN, with service module: No BGP: No VxLAN: No Multi Chassis Trunking (MCT): No DRAM: 1 GB NVRAM (Flash): 2 GB Packet buffer size: 8/10/12/24 port: 2 MB, 48 port: 4 MB Maximum MAC addresses: 16,384 Maximum VLANs: 4,095 Maximum PVLANs: 32 Maximum STP (spanning trees instances): 254 Maximum VEs: 382 Maximum ARP entries: 4,094 Maximum routes (in hardware): 1,000 (IPv4), 1,000 (IPv6) Next hop address: 4,094 Trunking: Maximum ports per trunk: 8 Maximum trunk groups: 128 Maximum jumbo frame size: 9,216 bytes QoS priority queues: 8 per port Multicast groups: 3,072 (Layer 2) 2,048 (Layer 3) Quality of Service (QoS): • ACL Mapping and Marking of ToS/DSCP (CoS) • ACL Mapping and Marking of 802.1p • ACL Mapping to Priority Queue • Classifying and Limiting Flows Based on TCP Flags DiffServ Support • Honoring DSCP and 802.1p (CoS) • MAC Address Mapping to Priority Queue Priority Queue Management using Weighted Round Robin (WRR), Strict Priority (SP), and a combination of WRR and SP Traffic management: • ACL-based inbound rate limiting and traffic policies • Broadcast, multicast, and unknown unicast rate limiting • Inbound rate limiting per port Outbound rate limiting per port and per queue SDN features: • OpenFlow1 v1.0 and v1.3 • OpenFlow with hybrid port mode Operates with an OpenDayLight Controller High availability: • Layer 3 VRRP/VRRP-E protocol redundancy • Real-time state synchronization across the stack • Hitless failover and switchover from master to standby stack controller • Hot insertion and removal of stacked units • Layer 2 VSRP switch redundancy In Service Software Update (ISSU) Layer 2 feature set: • 802.1s Multiple Spanning Tree • 802.1x Authentication • Auto MDI/MDIX • BPDU Guard, Root Guard • Dual-Mode VLANs • MAC-based VLANs, Dynamic MAC-based VLAN activation • Dynamic VLAN Assignment • Dynamic Voice VLAN Assignment • Fast Port Span • GVRP: GARP VLAN Registration Protocol • IGMP Snooping (v1/v2/v3) • IGMP Proxy for Static Groups • IGMP v2/v3 Fast Leave • Inter-Packet Gap (IPG) adjustment • Link Fault Signaling (LFS) • MAC Address Filtering MAC Learning Disable • MLD Snooping (v1/v2) • Multi-device Authentication • Per-VLAN Spanning Tree (PVST/PVST+/PRST) Mirroring: Port-based, ACL-based, MAC Filter-based, and • VLAN-based • PIM-SM v2 Snooping • Port Loop Detection • Private VLAN • Remote Fault Notification (RFN) • Single-instance Spanning Tree • Trunk Groups (static, LACP) • Uni-Directional Link Detection (UDLD) • Metro-Ring Protocol (MRP) (v1, v2) • Virtual Switch Redundancy Protocol (VSRP) • Q-in-Q and selective Q-in-Q • VLAN Mapping Topology Groups Base Layer 3 IP routing feature set: • IPv4 and IPv6 static routes • – RIP v1/v2, RIPng • ECMP • Port-based Access Control Lists Layer 3/Layer 4 ACLs • Host routes • Virtual Interfaces • Routed Interfaces • Route-only Support Routing Between Directly Connected Subnets Premium Layer 3 IP routing feature set with software license: • IPv4 and IPv6 dynamic routes • OSPF v2, v3 • PIM-SM, PIM-SSM, PIM-DM, PIM passive (IPv4, IPv6) PBR • Virtual Route Redundancy Protocol VRRP (IPv4) • VRRP v3 (IPv6) VRRP-E(IPv4/IPv6) MTBF (25°C): 562,889 hours |
| Dimensions | 105 mm × 27.6 mm × 83.1 mm (4.1'' × 1.1'' × 3.3'') | 440 (W) × 280 (D) × 43.65 (H) mm | 440 (W) × 280 (D) × 43.65 (H) mm | 269 (W) × 213 (D) × 43.4 (H) mm |
| Weight | 0.265 kg (0.58 lb) | 3.8 kg | 3.8 kg | 2.58 kg |
| Ordering Information | — | RUCKUS ICX 7150 Switch, 24×10/100/1000 Mbps ports, 2×1 GbE RJ45 uplink-ports, 4×1 GbE SFP uplink-ports upgradable to up to 4×10 GbE SFP+ with license, basic Layer 3 (static routing and RIP). | — | — |
| Power | • Power Supply: 48 V DC, 0.8 A • Max. Power Consumption: 38 W • Power Consumption in Idle: 3 W | Power supply rated maximum (AC): 36 W Switch power consumption (25°C): • Idle (no PoE load): 14 W • 10% traffic (full PoE load): 24 W • 100% traffic (full PoE load): 24 W Switch heat dissipation (25°C): • Idle (no PoE load): 47 BTU/hr • 10% traffic (full PoE load): 81 BTU/hr • 100% traffic (full PoE load): 82 BTU/hr | Power supply rated maximum (AC): 36 W Switch power consumption (25°C): • Idle (no PoE load): 14 W • 10% traffic (full PoE load): 24 W • 100% traffic (full PoE load): 24 W Switch heat dissipation (25°C): • Idle (no PoE load): 47 BTU/hr • 10% traffic (full PoE load): 81 BTU/hr • 100% traffic (full PoE load): 82 BTU/hr | Power supply rated maximum (AC): 150 W Switch power consumption (25°C): • Idle (no PoE load): 20 W • 10% traffic (full PoE load): 157 W • 100% traffic (full PoE load): 157 W Switch heat dissipation (25°C): • Idle (no PoE load): 69 BTU/hr • 10% traffic (full PoE load): 78 BTU/hr • 100% traffic (full PoE load): 79 BTU/hr |